Filtered by vendor Schneider-electric
Subscriptions
Total
795 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-13901 | 1 Schneider-electric | 2 Modicon M241/m251, Modicon M262 | 2026-03-11 | N/A |
| CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels. | ||||
| CVE-2025-13957 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2026-03-11 | N/A |
| CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default. | ||||
| CVE-2026-1286 | 1 Schneider-electric | 1 Foxboro Dcs | 2026-03-11 | N/A |
| CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file. | ||||
| CVE-2025-11739 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reporting And Dashboards | 2026-03-11 | N/A |
| CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization. | ||||
| CVE-2025-13902 | 1 Schneider-electric | 2 Modicon Controllers M241/m251, Modicon Controllers M258/lmc058 | 2026-03-11 | N/A |
| CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload. | ||||
| CVE-2026-2273 | 1 Schneider-electric | 1 Ecostruxure Automation Expert | 2026-03-11 | N/A |
| CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file. | ||||
| CVE-2025-13844 | 1 Schneider-electric | 1 Ecostruxure Power Build - Rapsody | 2026-03-03 | 5.3 Medium |
| CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody. | ||||
| CVE-2023-6407 | 2 Microsoft, Schneider-electric | 6 Windows 10 1507, Windows 11 21h2, Windows Server 2016 and 3 more | 2026-02-25 | 5.3 Medium |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker. | ||||
| CVE-2026-1227 | 1 Schneider-electric | 2 Ecostruxure Building Operation Webstation, Ecostruxure Building Operation Workstation | 2026-02-11 | N/A |
| CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized disclosure of local files, interaction within the EBO system, or denial of service conditions when a local user uploads a specially crafted TGML graphics file to the EBO server from Workstation. | ||||
| CVE-2026-1226 | 1 Schneider-electric | 2 Ecostruxure Building Operation Webstation, Ecostruxure Building Operation Workstation | 2026-02-11 | N/A |
| CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file. | ||||
| CVE-2025-13905 | 1 Schneider-electric | 2 Ecostruxure Process Expert, Ecostruxure Process Expert For Aveva System Platform | 2026-01-30 | N/A |
| CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart. | ||||
| CVE-2025-13845 | 1 Schneider-electric | 1 Ecostruxure Power Build - Rapsody | 2026-01-16 | N/A |
| CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody. | ||||
| CVE-2018-1124 | 6 Canonical, Debian, Opensuse and 3 more | 13 Ubuntu Linux, Debian Linux, Leap and 10 more | 2025-12-18 | 7.8 High |
| procps-ng before version 3.3.15 is vulnerable to multiple integer overflows leading to a heap corruption in file2strvec function. This allows a privilege escalation for a local attacker who can create entries in procfs by starting processes, which could result in crashes or arbitrary code execution in proc utilities run by other users. | ||||
| CVE-2018-1126 | 5 Canonical, Debian, Procps-ng Project and 2 more | 13 Ubuntu Linux, Debian Linux, Procps-ng and 10 more | 2025-12-17 | N/A |
| procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124. | ||||
| CVE-2025-11567 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2025-11-14 | N/A |
| CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured. | ||||
| CVE-2025-11566 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2025-11-12 | N/A |
| CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint. | ||||
| CVE-2025-11565 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2025-11-12 | N/A |
| CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload. | ||||
| CVE-2014-5413 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-11-04 | N/A |
| Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm. | ||||
| CVE-2014-5412 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-11-04 | N/A |
| Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account. | ||||
| CVE-2014-5411 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-11-04 | N/A |
| Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors. | ||||