| CVE-2013-2763 | 1 Schneider-electric | 24 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 21 more | 2025-04-11 | N/A |
| The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be duplicated" and "an attacker could not remotely exploit this observed behavior to deny PLC control functions. | ||||
| CVE-2013-2762 | 1 Schneider-electric | 1 Magelis Xbt Hmi | 2025-04-11 | N/A |
| The Schneider Electric Magelis XBT HMI controller has a default password for authentication of configuration uploads, which makes it easier for remote attackers to bypass intended access restrictions via crafted configuration data. | ||||
| CVE-2013-0664 | 1 Schneider-electric | 3 Modicon M340, Modicon Premium, Modicon Quantum Plc | 2025-04-11 | N/A |
| The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests. | ||||
| CVE-2013-0658 | 1 Schneider-electric | 1 Accutech Manager | 2025-04-11 | N/A |
| Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request. | ||||
| CVE-2013-2824 | 1 Schneider-electric | 4 Citectscada, Powerlogic Scada, Struxureware Powerscada Expert and 1 more | 2025-04-11 | N/A |
| Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet. | ||||
| CVE-2013-2796 | 1 Schneider-electric | 3 Citectscada, Powerlogic Scada, Vijeo Citect | 2025-04-11 | N/A |
| Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue. | ||||
| CVE-2013-0655 | 1 Schneider-electric | 1 Software Update Utility | 2025-04-11 | N/A |
| The client in Schneider Electric Software Update (SESU) Utility 1.0.x and 1.1.x does not ensure that updates have a valid origin, which allows man-in-the-middle attackers to spoof updates, and consequently execute arbitrary code, by modifying the data stream on TCP port 80. | ||||
| CVE-2023-3001 | 1 Schneider-electric | 1 Igss Dashboard | 2025-03-05 | 7.8 High |
| A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file. | ||||
| CVE-2022-34755 | 1 Schneider-electric | 1 Easergy Builder Installer | 2025-03-03 | 6.3 Medium |
| A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker with a local privileged account to place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code during the installation process initiated by a valid user. Affected Products: Easergy Builder Installer (1.7.23 and prior) | ||||
| CVE-2023-25548 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-03-03 | 8.8 High |
| A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
| CVE-2023-25552 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-03-03 | 8.1 High |
| A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized content, changes or deleting of content, or performing unauthorized functions when tampering the Device File Transfer settings on DCE endpoints. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
| CVE-2023-25549 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-03-03 | 7.2 High |
| A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
| CVE-2023-4516 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-27 | 7.8 High |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update Service that could allow a local attacker to change update source, potentially leading to remote code execution when the attacker force an update containing malicious content. | ||||
| CVE-2023-5402 | 1 Schneider-electric | 1 C-bus Toolkit | 2025-02-27 | 9.8 Critical |
| A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote code execution when the transfer command is used over the network. | ||||
| CVE-2023-5399 | 1 Schneider-electric | 1 Spacelogic C-bus Toolkit | 2025-02-27 | 9.8 Critical |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause tampering of files on the personal computer running C-Bus when using the File Command. | ||||
| CVE-2023-5391 | 1 Schneider-electric | 3 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports, Ecostruxure Power Scada Operation With Advanced Reports | 2025-02-27 | 9.8 Critical |
| A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application. | ||||
| CVE-2023-25551 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-02-12 | 6.1 Medium |
| A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
| CVE-2023-25550 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-02-12 | 7.2 High |
| A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
| CVE-2023-25554 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-02-12 | 7.8 High |
| A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
| CVE-2023-25547 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-02-12 | 8.8 High |
| A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||