Filtered by vendor Schneider-electric
Subscriptions
Total
784 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2015-0998 | 2 Aveva, Schneider-electric | 2 Aveva Edge, Wonderware Intouch 2014 | 2025-04-12 | N/A |
| Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network. | ||||
| CVE-2013-0662 | 2 Schneider-electric, Schneider Electric | 13 Concept, Modbus Serial Driver, Modbuscommdtm Sl and 10 more | 2025-04-12 | N/A |
| Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header. | ||||
| CVE-2015-0997 | 2 Aveva, Schneider-electric | 2 Aveva Edge, Wonderware Intouch 2014 | 2025-04-12 | N/A |
| Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guessing attack. | ||||
| CVE-2014-8390 | 1 Schneider-electric | 1 Vampset | 2025-04-12 | N/A |
| Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file. | ||||
| CVE-2016-2292 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2025-04-12 | 6.5 Medium |
| Stack-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors. | ||||
| CVE-2014-9206 | 1 Schneider-electric | 1 Device Type Manager | 2025-04-12 | N/A |
| Stack-based buffer overflow in Device Type Manager (DTM) 3.1.6 and earlier for Schneider Electric Invensys SRD Control Valve Positioner devices 960 and 991 allows local users to gain privileges via a malformed DLL file. | ||||
| CVE-2016-4520 | 1 Schneider-electric | 1 Pelco Digital Sentry Video Management System Firmware | 2025-04-12 | N/A |
| Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14 has hardcoded credentials, which allows remote attackers to obtain access, and consequently execute arbitrary code, via unspecified vectors. | ||||
| CVE-2016-2290 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2025-04-12 | 8.8 High |
| Heap-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors. | ||||
| CVE-2015-8561 | 1 Schneider-electric | 1 Proclima | 2025-04-12 | N/A |
| The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918. | ||||
| CVE-2015-3963 | 2 Schneider-electric, Windriver | 14 Sage 1210, Sage 1230, Sage 1250 and 11 more | 2025-04-12 | N/A |
| Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value. | ||||
| CVE-2015-3977 | 1 Schneider-electric | 1 Imt25 Magnetic Flow Dtm | 2025-04-12 | N/A |
| Buffer overflow in Schneider Electric IMT25 Magnetic Flow DTM before 1.500.004 for the HART Protocol allows remote authenticated users to execute arbitrary code or cause a denial of service (memory corruption) via a crafted HART reply. | ||||
| CVE-2015-3962 | 1 Schneider-electric | 1 Struxureware Building Expert Multi-purpose Management | 2025-04-12 | N/A |
| Schneider Electric StruxureWare Building Expert MPM before 2.15 does not use encryption for the client-server data stream, which allows remote attackers to discover credentials by sniffing the network. | ||||
| CVE-2015-7918 | 1 Schneider-electric | 1 Proclima | 2025-04-12 | N/A |
| Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561. | ||||
| CVE-2015-3940 | 1 Schneider-electric | 1 Wonderware System Platform 2014 | 2025-04-12 | N/A |
| Untrusted search path vulnerability in Schneider Electric Wonderware System Platform before 2014 R2 Patch 01 allows local users to gain privileges via a Trojan horse DLL in an unspecified directory. | ||||
| CVE-2015-0996 | 2 Aveva, Schneider-electric | 2 Aveva Edge, Wonderware Intouch 2014 | 2025-04-12 | N/A |
| Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password. | ||||
| CVE-2016-2291 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2025-04-12 | 6.5 Medium |
| Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allow remote attackers to execute arbitrary code or cause a denial of service (out-of-bounds read) via unspecified vectors. | ||||
| CVE-2015-0982 | 1 Schneider-electric | 1 Pelco Ds-nv | 2025-04-12 | N/A |
| Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors. | ||||
| CVE-2015-7921 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2025-04-12 | 9.1 Critical |
| The FTP server in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 has hardcoded credentials, which makes it easier for remote attackers to bypass authentication by leveraging knowledge of these credentials. | ||||
| CVE-2014-8511 | 1 Schneider-electric | 1 Proclima | 2025-04-12 | N/A |
| Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers. | ||||
| CVE-2015-6485 | 1 Schneider-electric | 8 Sage 1410, Sage 1430, Sage 1450 and 5 more | 2025-04-12 | N/A |
| Schneider Electric Telvent Sage 2300 RTUs with firmware before C3413-500-S01, and LANDAC II-2, Sage 1410, Sage 1430, Sage 1450, Sage 2400, and Sage 3030M RTUs with firmware before C3414-500-S02J2, allow remote attackers to obtain sensitive information from device memory by reading a padding field of an Ethernet packet. | ||||