A vulnerability has been identified in COMOS V10.6 (All versions), COMOS V10.6 (All versions), JT Bi-Directional Translator for STEP (All versions), NX V2412 (All versions < V2412.8900 with Cloud Entitlement (bundled as NX X)), NX V2506 (All versions < V2506.6000 with Cloud Entitlement (bundled as NX X)), Simcenter 3D (All versions < V2506.6000 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Femap (All versions < V2506.0002 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Studio (All versions), Simcenter System Architect (All versions), Tecnomatix Plant Simulation (All versions < V2504.0007). The SALT SDK is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
History

Wed, 10 Dec 2025 18:00:00 +0000

Type Values Removed Values Added
First Time appeared Siemens
Siemens comos
Siemens nx
Siemens simcenter 3d
Siemens simcenter Amesim
Siemens simcenter Femap
Siemens simcenter Studio
Siemens simcenter System Architect
Siemens tecnomatix Plant Simulation
Vendors & Products Siemens
Siemens comos
Siemens nx
Siemens simcenter 3d
Siemens simcenter Amesim
Siemens simcenter Femap
Siemens simcenter Studio
Siemens simcenter System Architect
Siemens tecnomatix Plant Simulation

Tue, 09 Dec 2025 15:15:00 +0000

Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}


Tue, 09 Dec 2025 11:00:00 +0000

Type Values Removed Values Added
Description A vulnerability has been identified in COMOS V10.6 (All versions), COMOS V10.6 (All versions), JT Bi-Directional Translator for STEP (All versions), NX V2412 (All versions < V2412.8900 with Cloud Entitlement (bundled as NX X)), NX V2506 (All versions < V2506.6000 with Cloud Entitlement (bundled as NX X)), Simcenter 3D (All versions < V2506.6000 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Femap (All versions < V2506.0002 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Studio (All versions), Simcenter System Architect (All versions), Tecnomatix Plant Simulation (All versions < V2504.0007). The SALT SDK is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
Weaknesses CWE-295
References
Metrics cvssV3_1

{'score': 8.1, 'vector': 'CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H'}

cvssV4_0

{'score': 9.2, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N'}


cve-icon MITRE

Status: PUBLISHED

Assigner: siemens

Published: 2025-12-09T10:44:24.727Z

Updated: 2025-12-09T14:26:55.244Z

Reserved: 2025-04-16T08:50:26.973Z

Link: CVE-2025-40801

cve-icon Vulnrichment

Updated: 2025-12-09T14:26:52.670Z

cve-icon NVD

Status : Awaiting Analysis

Published: 2025-12-09T16:17:45.357

Modified: 2025-12-09T18:36:53.557

Link: CVE-2025-40801

cve-icon Redhat

No data.