Filtered by CWE-798
Total 1554 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2019-11946 1 Hp 1 Intelligent Management Center 2024-11-21 N/A
A remote credential disclosure vulnerability was identified in HPE Intelligent Management Center (IMC) PLAT earlier than version 7.3 E0506P09.
CVE-2019-11898 1 Bosch 1 Access 2024-11-21 9.9 Critical
Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8.
CVE-2019-11030 1 Mirasys 1 Mirasys Vms 2024-11-21 N/A
Mirasys VMS before V7.6.1 and 8.x before V8.3.2 mishandles the Mirasys.Common.Utils.Security.DataCrypt method in Common.dll in AuditTrailService in SMServer.exe. This method triggers insecure deserialization within the .NET garbage collector, in which a gadget (contained in a serialized object) may be executed with SYSTEM privileges. The attacker must properly encrypt the object; however, the hardcoded keys are available.
CVE-2019-10995 1 Abb 16 Cp651, Cp651-web, Cp651-web Firmware and 13 more 2024-11-21 8.8 High
ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface.
CVE-2019-10990 1 Redlion 1 Crimson 2024-11-21 6.5 Medium
Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, uses a hard-coded password to encrypt protected files in transit and at rest, which may allow an attacker to access configuration files.
CVE-2019-10979 1 Sick 2 Msc800, Msc800 Firmware 2024-11-21 N/A
SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.
CVE-2019-10920 1 Siemens 2 Logo\!8 Bm, Logo\!8 Bm Firmware 2024-11-21 7.5 High
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-10881 1 Xerox 20 Altalink B8045, Altalink B8045 Firmware, Altalink B8055 and 17 more 2024-11-21 9.8 Critical
Xerox AltaLink B8045/B8055/B8065/B8075/B8090, AltaLink C8030/C8035/C8045/C8055/C8070 with software releases before 103.xxx.030.32000 includes two accounts with weak hard-coded passwords which can be exploited and allow unauthorized access which cannot be disabled.
CVE-2019-10851 1 Computrols 1 Computrols Building Automation Software 2024-11-21 N/A
Computrols CBAS 18.0.0 has hard-coded encryption keys.
CVE-2019-10850 1 Computrols 1 Computrols Building Automation Software 2024-11-21 N/A
Computrols CBAS 18.0.0 has Default Credentials.
CVE-2019-10712 1 Wago 32 750-330, 750-330 Firmware, 750-352 and 29 more 2024-11-21 N/A
The Web-GUI on WAGO Series 750-88x (750-330, 750-352, 750-829, 750-831, 750-852, 750-880, 750-881, 750-882, 750-884, 750-885, 750-889) and Series 750-87x (750-830, 750-849, 750-871, 750-872, 750-873) devices has undocumented service access.
CVE-2019-10694 1 Puppet 1 Puppet Enterprise 2024-11-21 9.8 Critical
The express install, which is the suggested way to install Puppet Enterprise, gives the user a URL at the end of the install to set the admin password. If they do not use that URL, there is an overlooked default password for the admin user. This was resolved in Puppet Enterprise 2019.0.3 and 2018.1.9.
CVE-2019-10688 1 Polycom 2 Better Together Over Ethernet Connector, Unified Communications Software 2024-11-21 N/A
VVX products with software versions including and prior to, UCS 5.9.2 with Better Together over Ethernet Connector (BToE) application 3.9.1, use hard-coded credentials to establish connections between the host application and the device.
CVE-2019-10479 1 Glory-global 2 Rbw-100, Rbw-100 Firmware 2024-11-21 N/A
An issue was discovered on Glory RBW-100 devices with firmware ISP-K05-02 7.0.0. A hard-coded username and password were identified that allow a remote attacker to gain admin access to the Front Circle Controller web interface.
CVE-2019-10011 1 Jenzabar 1 Internet Campus Solution 2024-11-21 N/A
ICS/StaticPages/AddTestUsers.aspx in Jenzabar JICS (aka Internet Campus Solution) before 2019-02-06 allows remote attackers to create an arbitrary number of accounts with a password of 1234.
CVE-2019-0022 1 Juniper 3 Advanced Threat Prevention, Atp400, Atp700 2024-11-21 N/A
Juniper ATP ships with hard coded credentials in the Cyphort Core instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
CVE-2019-0020 1 Juniper 3 Advanced Threat Prevention, Atp400, Atp700 2024-11-21 N/A
Juniper ATP ships with hard coded credentials in the Web Collector instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
CVE-2018-9195 1 Fortinet 2 Forticlient, Fortios 2024-11-21 5.9 Medium
Use of a hardcoded cryptographic key in the FortiGuard services communication protocol may allow a Man in the middle with knowledge of the key to eavesdrop on and modify information (URL/SPAM services in FortiOS 5.6, and URL/SPAM/AV services in FortiOS 6.0.; URL rating in FortiClient) sent and received from Fortiguard severs by decrypting these messages. Affected products include FortiClient for Windows 6.0.6 and below, FortiOS 6.0.7 and below, FortiClient for Mac OS 6.2.1 and below.
CVE-2018-9161 1 Prismaindustriale 1 Checkweigher Prismaweb 2024-11-21 N/A
Prisma Industriale Checkweigher PrismaWEB 1.21 allows remote attackers to discover the hardcoded prisma password for the prismaweb account by reading user/scripts/login_par.js.
CVE-2018-9149 1 Zyxel 2 Ac3000, Ac3000 Firmware 2024-11-21 N/A
The Zyxel Multy X (AC3000 Tri-Band WiFi System) device doesn't use a suitable mechanism to protect the UART. After an attacker dismantles the device and uses a USB-to-UART cable to connect the device, he can use the 1234 password for the root account to login to the system. Furthermore, an attacker can start the device's TELNET service as a backdoor.