Filtered by CWE-200
Total 9888 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2021-23890 1 Mcafee 1 Epolicy Orchestrator 2024-11-21 6.5 Medium
Information leak vulnerability in the Agent Handler of McAfee ePolicy Orchestrator (ePO) prior to 5.10 Update 10 allows an unauthenticated user to download McAfee product packages (specifically McAfee Agent) available in ePO repository and install them on their own machines to have it managed and then in turn get policy details from the ePO server. This can only happen when the ePO Agent Handler is installed in a Demilitarized Zone (DMZ) to service machines not connected to the network through a VPN.
CVE-2021-23858 1 Bosch 24 Indracontrol Xlc, Indracontrol Xlc Firmware, Rexroth Indramotion Mlc L20 and 21 more 2024-11-21 8.6 High
Information disclosure: The main configuration, including users and their hashed passwords, is exposed by an unprotected web server resource and can be accessed without authentication. Additionally, device details are exposed which include the serial number and the firmware version by another unprotected web server resource.
CVE-2021-23855 1 Bosch 4 Rexroth Indramotion Mlc, Rexroth Indramotion Mlc Firmware, Rexroth Indramotion Xlc and 1 more 2024-11-21 8.6 High
The user and password data base is exposed by an unprotected web server resource. Passwords are hashed with a weak hashing algorithm and therefore allow an attacker to determine the password by using rainbow tables.
CVE-2021-23386 1 Dns-packet Project 1 Dns-packet 2024-11-21 7.7 High
This affects the package dns-packet before 5.2.2. It creates buffers with allocUnsafe and does not always fill them before forming network packets. This can expose internal application memory over unencrypted network when querying crafted invalid domain names.
CVE-2021-23204 1 Gallagher 1 Command Centre 2024-11-21 8.1 High
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Gallagher Command Centre Server allows OSDP key material to be exposed to Command Centre Operators. This issue affects: Gallagher Command Centre 8.40 versions prior to 8.40.1888 (MR3); 8.30 versions prior to 8.30.1359 (MR3).
CVE-2021-23193 1 Gallagher 1 Command Centre 2024-11-21 8.1 High
Improper privilege validation vulnerability in COM Interface of Gallagher Command Centre Server allows authenticated unprivileged operators to retrieve sensitive information from the Command Centre Server. This issue affects: Gallagher Command Centre 8.50 versions prior to 8.50.2048 (MR3) ; 8.40 versions prior to 8.40.2063 (MR4); 8.30 versions prior to 8.30.1454 (MR4) ; 8.20 versions prior to 8.20.1291 (MR6); version 8.10 and prior versions.
CVE-2021-22925 8 Apple, Fedoraproject, Haxx and 5 more 28 Mac Os X, Macos, Fedora and 25 more 2024-11-21 5.3 Medium
curl supports the `-t` command line option, known as `CURLOPT_TELNETOPTIONS`in libcurl. This rarely used option is used to send variable=content pairs toTELNET servers.Due to flaw in the option parser for sending `NEW_ENV` variables, libcurlcould be made to pass on uninitialized data from a stack based buffer to theserver. Therefore potentially revealing sensitive internal information to theserver using a clear-text network protocol.This could happen because curl did not call and use sscanf() correctly whenparsing the string provided by the application.
CVE-2021-22917 1 Brave 1 Browser 2024-11-21 6.5 Medium
Brave Browser Desktop between versions 1.17 and 1.20 is vulnerable to information disclosure by way of DNS requests in Tor windows not flowing through Tor if adblocking was enabled.
CVE-2021-22916 1 Brave 1 Brave 2024-11-21 5.9 Medium
In Brave Desktop between versions 1.17 and 1.26.60, when adblocking is enabled and a proxy browser extension is installed, the CNAME adblocking feature issues DNS requests that used the system DNS settings instead of the extension's proxy settings, resulting in possible information disclosure.
CVE-2021-22913 1 Nextcloud 1 Deck 2024-11-21 6.5 Medium
Nextcloud Deck before 1.2.7, 1.4.1 suffers from an information disclosure vulnerability when searches for sharees utilize the lookup server by default instead of only the local Nextcloud server unless a global search has been explicitly chosen by the user.
CVE-2021-22912 1 Nextcloud 1 Nextcloud 2024-11-21 6.5 Medium
Nextcloud iOS before 3.4.2 suffers from an information disclosure vulnerability when searches for sharees utilize the lookup server by default instead of only on the local Nextcloud server unless a global search has been explicitly chosen by the user.
CVE-2021-22905 1 Nextcloud 1 Nextcloud 2024-11-21 6.5 Medium
Nextcloud Android App (com.nextcloud.client) before v3.16.0 is vulnerable to information disclosure due to searches for sharees being performed by default on the lookup server instead of only using the local Nextcloud server unless a global search has been explicitly chosen by the user.
CVE-2021-22898 7 Debian, Fedoraproject, Haxx and 4 more 13 Debian Linux, Fedora, Curl and 10 more 2024-11-21 3.1 Low
curl 7.7 through 7.76.1 suffers from an information disclosure when the `-t` command line option, known as `CURLOPT_TELNETOPTIONS` in libcurl, is used to send variable=content pairs to TELNET servers. Due to a flaw in the option parser for sending NEW_ENV variables, libcurl could be made to pass on uninitialized data from a stack based buffer to the server, resulting in potentially revealing sensitive internal information to the server using a clear-text network protocol.
CVE-2021-22892 1 Rocket.chat 1 Rocket.chat 2024-11-21 7.5 High
An information disclosure vulnerability exists in the Rocket.Chat server fixed v3.13, v3.12.2 & v3.11.3 that allowed email addresses to be disclosed by enumeration and validation checks.
CVE-2021-22885 3 Debian, Redhat, Rubyonrails 4 Debian Linux, Satellite, Actionpack Page-caching and 1 more 2024-11-21 7.5 High
A possible information disclosure / unintended method execution vulnerability in Action Pack >= 2.0.0 when using the `redirect_to` or `polymorphic_url`helper with untrusted user input.
CVE-2021-22815 1 Schneider-electric 55 Ap9922 Battery Management System, Apc Rack Power Distribution Units, Galaxy 3500 and 52 more 2024-11-21 5.3 Medium
A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
CVE-2021-22793 1 Schneider-electric 5 Accusine Pcs\+, Accusine Pcsn, Accusine Pcsn Active Harmonic Filter Firmware and 2 more 2024-11-21 7.2 High
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol.
CVE-2021-22785 1 Schneider-electric 28 140cpu65150, 140cpu65150 Firmware, 140noc77101 and 25 more 2024-11-21 7.5 High
A CWE-200: Information Exposure vulnerability exists that could cause sensitive information of files located in the web root directory to leak when an attacker sends a HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors with integrated Ethernet (Copro): TSXP574634, TSXP575634, TSXP576634 (All Versions), Modicon Quantum Processors with Integrated Ethernet (Copro): 140CPU65xxxxx (All Versions), Modicon Quantum Communication Modules: 140NOE771x1, 140NOC78x00, 140NOC77101 (All Versions), Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 (All Versions)
CVE-2021-22783 1 Schneider-electric 1 Ritto Wiser Door 2024-11-21 8.8 High
A CWE-200: Information Exposure vulnerability exists which could allow a session hijack when the door panel is communicating with the door. Affected Product: Ritto Wiser Door (All versions)
CVE-2021-22770 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2024-11-21 6.5 Medium
A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitly authorized to have access to that information.