Filtered by CWE-787
Total 13473 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-41111 1 Samsung 32 Exynos 1080, Exynos 1080 Firmware, Exynos 1280 and 29 more 2024-11-21 7.1 High
An issue was discovered in Samsung Mobile Processor, Wearable Processor, Automotive Processor, and Modem (Exynos 9810, 9610, 9820, 980, 850, 1080, 2100, 2200, 1280, 1380, 1330, 9110, W920, Modem 5123, Modem 5300, and Auto T5123). Improper handling of a length parameter inconsistency can cause abnormal termination of a mobile phone. This occurs in the RLC task and RLC module.
CVE-2023-41101 1 Opennds 1 Opennds 2024-11-21 9.8 Critical
An issue was discovered in the captive portal in OpenNDS before version 10.1.3. get_query in http_microhttpd.c does not validate the length of the query string of GET requests. This leads to a stack-based buffer overflow in versions 9.x and earlier, and to a heap-based buffer overflow in versions 10.x and later. Attackers may exploit the issue to crash OpenNDS (Denial-of-Service condition) or to inject and execute arbitrary bytecode (Remote Code Execution). Affected OpenNDS before version 10.1.3 fixed in OpenWrt master and OpenWrt 23.05 on 23. November by updating OpenNDS to version 10.2.0.
CVE-2023-41028 1 Juplink 2 Rx4-1500, Rx4-1500 Firmware 2024-11-21 9 Critical
A stack-based buffer overflow exists in Juplink RX4-1500, a WiFi router, in versions 1.0.2 through 1.0.5. An authenticated attacker can exploit this vulnerability to achieve code execution as root.
CVE-2023-40942 2 Tenda, Tendacn 3 Ac9v3.0br, Ac9, Ac9 Firmware 2024-11-21 9.8 Critical
Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/SetFirewallCfg.
CVE-2023-40915 1 Tenda 2 Ax3, Ax3 Firmware 2024-11-21 7.5 High
Tenda AX3 v16.03.12.11 has a stack buffer overflow vulnerability detected at function form_fast_setting_wifi_set. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ssid parameter.
CVE-2023-40904 1 Tenda 2 Ac10v4, Ac10v4 Firmware 2024-11-21 9.8 Critical
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
CVE-2023-40902 1 Tenda 2 Ac10v4, Ac10v4 Firmware 2024-11-21 9.8 Critical
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
CVE-2023-40901 1 Tenda 3 Ac10, Ac10v4, Ac10v4 Firmware 2024-11-21 9.8 Critical
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg.
CVE-2023-40857 1 Virustotal 1 Yara 2024-11-21 8.8 High
Buffer Overflow vulnerability in VirusTotal yara v.4.3.2 allows a remote attacker to execute arbtirary code via the yr_execute_cod function in the exe.c component.
CVE-2023-40848 1 Tenda 2 Ac6, Ac6 Firmware 2024-11-21 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "sub_7D858."
CVE-2023-40847 1 Tenda 2 Ac6, Ac6 Firmware 2024-11-21 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "initIpAddrInfo." In the function, it reads in a user-provided parameter, and the variable is passed to the function without any length check.
CVE-2023-40846 1 Tenda 2 Ac6, Ac6 Firmware 2024-11-21 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function sub_90998.
CVE-2023-40845 1 Tenda 2 Ac6, Ac6 Firmware 2024-11-21 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'sub_34FD0.' In the function, it reads user provided parameters and passes variables to the function without any length checks.
CVE-2023-40844 1 Tenda 2 Ac6, Ac6 Firmware 2024-11-21 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'formWifiBasicSet.'
CVE-2023-40843 1 Tenda 2 Ac6, Ac6 Firmware 2024-11-21 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "sub_73004."
CVE-2023-40842 1 Tenda 2 Ac6, Ac6 Firmware 2024-11-21 9.8 Critical
Tengda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "R7WebsSecurityHandler."
CVE-2023-40841 1 Tenda 2 Ac6, Ac6 Firmware 2024-11-21 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "add_white_node,"
CVE-2023-40840 1 Tenda 2 Ac6, Ac6 Firmware 2024-11-21 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "fromGetWirelessRepeat."
CVE-2023-40802 1 Tenda 2 Ac23, Ac23 Firmware 2024-11-21 6.5 Medium
The get_parentControl_list_Info function does not verify the parameters entered by the user, causing a post-authentication heap overflow vulnerability in Tenda AC23 v16.03.07.45_cn
CVE-2023-40799 1 Tenda 2 Ac23, Ac23 Firmware 2024-11-21 9.8 Critical
Tenda AC23 Vv16.03.07.45_cn is vulnerable to Buffer Overflow via sub_450A4C function.