Total
13473 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2023-42528 | 1 Samsung | 1 Android | 2024-11-21 | 6.7 Medium |
| Improper Input Validation vulnerability in ProcessNvBuffering of libsec-ril prior to SMR Nov-2023 Release 1 allows local attacker to execute arbitrary code. | ||||
| CVE-2023-42507 | 1 Jtekt | 1 Onsinview2 | 2024-11-21 | 7.8 High |
| Stack-based buffer overflow vulnerability exists in OnSinView2 versions 2.0.1 and earlier. If this vulnerability is exploited, information may be disclosed or arbitrary code may be executed by having a user open a specially crafted OnSinView2 project file. | ||||
| CVE-2023-42443 | 1 Vyperlang | 1 Vyper | 2024-11-21 | 8.1 High |
| Vyper is a Pythonic Smart Contract Language for the Ethereum Virtual Machine (EVM). In version 0.3.9 and prior, under certain conditions, the memory used by the builtins `raw_call`, `create_from_blueprint` and `create_copy_of` can be corrupted. For `raw_call`, the argument buffer of the call can be corrupted, leading to incorrect `calldata` in the sub-context. For `create_from_blueprint` and `create_copy_of`, the buffer for the to-be-deployed bytecode can be corrupted, leading to deploying incorrect bytecode. Each builtin has conditions that must be fulfilled for the corruption to happen. For `raw_call`, the `data` argument of the builtin must be `msg.data` and the `value` or `gas` passed to the builtin must be some complex expression that results in writing to the memory. For `create_copy_of`, the `value` or `salt` passed to the builtin must be some complex expression that results in writing to the memory. For `create_from_blueprint`, either no constructor parameters should be passed to the builtin or `raw_args` should be set to True, and the `value` or `salt` passed to the builtin must be some complex expression that results in writing to the memory. As of time of publication, no patched version exists. The issue is still being investigated, and there might be other cases where the corruption might happen. When the builtin is being called from an `internal` function `F`, the issue is not present provided that the function calling `F` wrote to memory before calling `F`. As a workaround, the complex expressions that are being passed as kwargs to the builtin should be cached in memory prior to the call to the builtin. | ||||
| CVE-2023-41712 | 1 Sonicwall | 61 Nsa2700, Nsa3700, Nsa4700 and 58 more | 2024-11-21 | 6.5 Medium |
| SonicOS post-authentication Stack-Based Buffer Overflow Vulnerability in the SSL VPN plainprefs.exp URL endpoint leads to a firewall crash. | ||||
| CVE-2023-41711 | 1 Sonicwall | 61 Nsa2700, Nsa3700, Nsa4700 and 58 more | 2024-11-21 | 6.5 Medium |
| SonicOS post-authentication Stack-Based Buffer Overflow Vulnerability in the sonicwall.exp, prefs.exp URL endpoints lead to a firewall crash. | ||||
| CVE-2023-41563 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2024-11-21 | 9.8 Critical |
| Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. | ||||
| CVE-2023-41562 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2024-11-21 | 9.8 Critical |
| Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. | ||||
| CVE-2023-41561 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2024-11-21 | 9.8 Critical |
| Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. | ||||
| CVE-2023-41560 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg. | ||||
| CVE-2023-41559 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2024-11-21 | 9.8 Critical |
| Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. | ||||
| CVE-2023-41558 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg. | ||||
| CVE-2023-41557 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac7 and 1 more | 2024-11-21 | 9.8 Critical |
| Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat. | ||||
| CVE-2023-41556 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2024-11-21 | 9.8 Critical |
| Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. | ||||
| CVE-2023-41555 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet. | ||||
| CVE-2023-41554 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet. | ||||
| CVE-2023-41553 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2024-11-21 | 9.8 Critical |
| Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg. | ||||
| CVE-2023-41552 | 1 Tenda | 4 Ac7, Ac7 Firmware, Ac9 and 1 more | 2024-11-21 | 9.8 Critical |
| Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set. | ||||
| CVE-2023-41307 | 1 Huawei | 2 Emui, Harmonyos | 2024-11-21 | 7.5 High |
| Memory overwriting vulnerability in the security module. Successful exploitation of this vulnerability may affect availability. | ||||
| CVE-2023-41273 | 1 Qnap | 3 Qts, Quts Hero, Qutscloud | 2024-11-21 | 5.5 Medium |
| A heap-based buffer overflow vulnerability has been reported to affect several QNAP operating system versions. If exploited, the vulnerability could allow authenticated administrators to execute code via a network. We have already fixed the vulnerability in the following versions: QTS 5.1.2.2533 build 20230926 and later QuTS hero h5.1.2.2534 build 20230927 and later QuTScloud c5.1.5.2651 and later | ||||
| CVE-2023-41140 | 1 Autodesk | 10 Autocad, Autocad Advance Steel, Autocad Architecture and 7 more | 2024-11-21 | 7.8 High |
| A maliciously crafted PRT file when parsed through Autodesk AutoCAD 2024 and 2023 can be used to cause a Heap-Based Buffer Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process. | ||||