Filtered by vendor Siemens Subscriptions
Total 2244 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2017-9942 1 Siemens 1 Sipass Integrated 2025-04-20 N/A
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with local access to the SiPass integrated server or SiPass integrated client to potentially obtain credentials from the systems.
CVE-2017-9941 1 Siemens 1 Sipass Integrated 2025-04-20 N/A
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.
CVE-2017-9940 1 Siemens 1 Sipass Integrated 2025-04-20 N/A
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with access to a low-privileged user account to read or write files on the file system of the SiPass integrated server over the network.
CVE-2017-9939 1 Siemens 1 Sipass Integrated 2025-04-20 N/A
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations.
CVE-2017-9938 1 Siemens 1 Simatic Logon 2025-04-20 N/A
A vulnerability was discovered in Siemens SIMATIC Logon (All versions before V1.6) that could allow specially crafted packets sent to the SIMATIC Logon Remote Access service on port 16389/tcp to cause a Denial-of-Service condition. The service restarts automatically.
CVE-2017-6458 4 Apple, Hpe, Ntp and 1 more 5 Mac Os X, Hpux-ntp, Ntp and 2 more 2025-04-20 8.8 High
Multiple buffer overflows in the ctl_put* functions in NTP before 4.2.8p10 and 4.3.x before 4.3.94 allow remote authenticated users to have unspecified impact via a long variable.
CVE-2017-6872 1 Siemens 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more 2025-04-20 N/A
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to access or alter historical measurement data stored on the device.
CVE-2017-6868 1 Siemens 1 Simatic Cp 44x-1 Redundant Network Access Modules 2025-04-20 N/A
An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process (CP) of the RNA series module, if network access to Port 102/TCP is available and the configuration file for the CP is stored on the RNA's CPU.
CVE-2017-6866 1 Siemens 1 Xhq Server 2025-04-20 N/A
A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceeding his configured permission level.
CVE-2017-6864 1 Siemens 1 Ruggedcom Rox I 2025-04-20 N/A
The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow an authenticated user to perform stored Cross-Site Scripting attacks.
CVE-2017-5712 3 Asus, Intel, Siemens 394 B150-a, B150-a Firmware, B150-plus and 391 more 2025-04-20 7.2 High
Buffer overflow in Active Management Technology (AMT) in Intel Manageability Engine Firmware 8.x/9.x/10.x/11.0/11.5/11.6/11.7/11.10/11.20 allows attacker with remote Admin access to the system to execute arbitrary code with AMT execution privilege.
CVE-2017-6873 1 Siemens 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more 2025-04-20 N/A
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp.
CVE-2017-2689 1 Siemens 1 Ruggedcom Rox I 2025-04-20 N/A
Siemens RUGGEDCOM ROX I (all versions) allow an authenticated user to bypass access restrictions in the web interface at port 10000/TCP to obtain privileged file system access or change configuration settings.
CVE-2017-2687 1 Siemens 1 Ruggedcom Rox I 2025-04-20 N/A
Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability in the integrated web server at port 10000/TCP which is prone to reflected Cross-Site Scripting attacks if an unsuspecting user is induced to click on a malicious link.
CVE-2017-2686 1 Siemens 1 Ruggedcom Rox I 2025-04-20 N/A
Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability that could allow an authenticated user to read arbitrary files through the web interface at port 10000/TCP and access sensitive information.
CVE-2017-2685 1 Siemens 3 Sinumerik Integrate Access Mymachine\/ethernet, Sinumerik Integrate Operate Client, Sinumerik Operate 2025-04-20 N/A
Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack.
CVE-2017-2684 1 Siemens 1 Simatic Logon 2025-04-20 N/A
Siemens SIMATIC Logon prior to V1.5 SP3 Update 2 could allow an attacker with knowledge of a valid user name, and physical or network access to the affected system, to bypass the application-level authentication.
CVE-2017-2683 1 Siemens 1 Ruggedcom Network Management Software 2025-04-20 N/A
A non-privileged user of the Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could perform a persistent Cross-Site Scripting (XSS) attack, potentially resulting in obtaining administrative permissions.
CVE-2017-2681 1 Siemens 155 Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware, Ek-ertec 200 Pn Io and 152 more 2025-04-20 6.5 Medium
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
CVE-2017-2680 1 Siemens 183 S110 Pn, Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware and 180 more 2025-04-20 6.5 Medium
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.